¼ö½Å Ư¼º¿¡ µû¸¥ ºÐ·ù
· GP ŸÀÔ: ÀϹݿë, °¨µµ¿Í ºÐÇØ´ÉÀ» ÀûÀýÈ÷ °®Ãß¾î ÃÊÀ½ÆÄ Å½»ó ÀÛ¾÷¿¡ ÀûÇÕ
· HR ŸÀÔ: ºÐÇØ´ÉÀ» »ì·Á Ç¥¸é ±ÙóÀÇ °áÇÔ Å½»óÀ̳ª µÎ²² ÃøÁ¤¿¡ ÀûÇÕ
· SHR ŸÀÔ: ºÐÇØ´ÉÀ» ÃÖ´ëÇÑ »ì·Á ÀÛÀº ºÎÇ°À̳ª Ç¥¸é ±ÙóÀÇ °áÇÔÀ» °Ë»çÇϴµ¥ ÀûÇÕ
· SP ŸÀÔ: ´ïÇÎÀ» °ÅÀÇ ¾ø¾Ö ¹ö¸° °íħÅõÇüÀ¸·Î °¨¼â°¡ ½ÉÇÑ ÀçÁú ȤÀº µÎ²¨¿î Á¦Ç°ÀÇ °Ë»ç¿¡ ÀûÇÕ

             
  104-1.jpg (11306 bytes)   104-2.jpg (12813 bytes)   104.jpg (14140 bytes)  
 
GP ½Ã¸®Áî
 
HR ½Ã¸®Áî
 
SP ½Ã¸®Áî
 
             


Standard Contact (¼öÁ÷ ŽÃËÀÚ)  



106.jpg (7154 bytes)106-2.jpg (11502 bytes)

           
         
C-0206-GP
C-0504-GP
C-0104-GP
C-0508-HR
C-0208-HR
         
C-0008-GP
C-0108-GP
C-0208-GP
C-0308-GP
C-0508-GP
   

   
Contact Fingertip(ÄÞÆÑÆ®Çü ¼öÁ÷ ŽÃËÀÚ)  



108-2.jpg (7332 bytes)108.jpg (11079 bytes)

 

      108-1.jpg (30671 bytes)
   
CF-0503-GP
CF-0204-GP
CF-0504-GP
CF-0502-GP
CF-0202-GP
         
CF-1002-GP
CF-0203-GP
CF-0502-CM

   
Fingertip Angle Beam Transducers(ÇΰÅÆÁ °æ»ç°¢ ŽÃËÀÚ)


 
   

   
Removable Delay Transducers(ºÐÇÒÇü ŽÃËÀÚ)
 
   

   
Fingertip Removable Angle Beam Transducers(Quick Change ŸÀÔ) - °æ»ç°¢ ŽÃËÀÚ


        
   

   
Fingertip Angle Beam Transducers(Captive Screw ŸÀÔ) - °æ»ç°¢ ŽÃËÀÚ

111-3.jpg (9051 bytes)111.jpg (16040 bytes)
111-2.jpg (28362 bytes)
   

   
Standard Angle Beam Transducers  

   

   
Delayline Transducers (µô·¹ÀÌ Å½ÃËÀÚ)   

 
   
 
GD-1002-HR
GRD-1002-HR
 
   

   
Protective Face Transducers (º¸È£Àç ŽÃËÀÚ)  

 
   

   
Immersion Transducers(¼öħ¿ë ŽÃËÀÚ)  

113-1.jpg (13232 bytes)113-2.jpg (11653 bytes) 113.jpg (55004 bytes)
   

   
Large Diameter Immersion(´ë±¸°æ ¼öħ¿ë ŽÃËÀÚ)



   

   
Slim type Immersion(½½¸²Çü ¼öħ¿ë ŽÃËÀÚ)  



   

   
¶óÀÎ Æ÷Ä¿½º ¼öħ¿ë ÃÊÀ½ÆÄ Å½ÃËÀÚ  
 
  ¶óÀÎ Æ÷Ä¿½º ¼öħ¿ë     ½½¸²Çü ¼öħ¿ë
   

   
¸Æ´Ö ºÎÂøÇü ŽÃËÀÚ  
5MHz, 0.25"
5MHz, 0.375"
2.25MHz, 0.375"
10MHz, 0.25"
   

   
ÃÊÀ½ÆÄ µÎ²² ÃøÁ¤±â¿ë ÃÊÀ½ÆÄ Å½ÃËÀÚ  

Technisonic ÃÊÀ½ÆÄ µÎ²² ÃøÁ¤¿ë ŽÃËÀÚ´Â ±âÁ¸ÀÇ Á¦Ç°¿¡ ¿¬°áÇÏ¿© »ç¿ëÇÒ ¼ö ÀÖ´Ù.
ŽÃËÀÚ Àü¹® Á¦Á¶ ¾÷üÀÇ Æ¯À¯ÇÑ ±â¼ú·Î °¨µµ¿Í ³»±¸¼ºÀÌ ÁÁÀº°ÍÀÌ ÀåÁ¡ÀÌ´Ù.
Potted CableÀÇ °æ¿ì ÄÉÀ̺íÀÌ ÀåÂøµÇ¾î ÀÖÀ¸³ª MD ŸÀÔÀÇ °æ¿ì ¸¶ÀÌÅ©·ÎµµÆ® ÄÉÀ̺íÀº Ãß°¡·Î ±¸ÀÔÇÏ¿©¾ß ÇÑ´Ù.
   

   
ÃÊÀ½ÆÄ µÎ²² ÃøÁ¤±â¿ë ÃÊÀ½ÆÄ Å½ÃËÀÚ  

 DRBPHT-0503-DL

5 MHz, .375" w/ 5' Top Mt. potted cable and plug, Bell Hsg. Temp range up to 500¡ÆF
 DRBHT-0503-DL 5 MHz, .375" w/ Bell Hsg. Top Mt. MD connector. Temp up to 500¡ÆF
 DFR-0503-DL Fingertip Style, 5 MHz, .375" w/ Rt. Angle MD conn. Temp up to 500¡ÆF
 DRBP-0502-DL 5 MHz, .25" w/ Bell Hsg and 5' Top Mt. potted cable and plug
 DFP-0502-DL Fingertip Style, 5 MHz, .25" w/ 5' potted cable and plug
 DFP-0702-DL Fingertip Style, 7.5 MHz, .25" w/ 5' potted cable and plug
 DFP-0503-DL Fingertip Style, 5 MHz, .375" w/ 5' potted cable and plug
 BHM-5-DL Dual cable with plug, 5', for DRBHT-0503-DL and DFR-0503-DL
   


ŽÃËÀÚ ÁÖº¯ ±â±¸
   
°¡º¯ °æ»ç°¢ Wedge
x-y Manipulator
Right Angle Adaptor(ISL)
Right Angle Adpator(IPU)
Waterproof(UHF)
Water Squirter
Magnet Holder
Search Tubes 10, 20, 30cm
Search Tube Connection
   

   
ÃÊÀ½ÆÄ ÄÉÀ̺í
BCB-2.0-58 BCB-2.0-74

BCM-2.0-74

BCX5-2.0-74

BNC/BNC, 2 m, RG 58 type BNC/BNC, 2 m, 174 type BNC/M'dot, 2 m, 174 type BNC/XTR5, 2 m, 174 type

XCX9-2.0-58
BCX9-2.0-58

BCUW-2.0-58

BCU-2.0-58

XTR/XTR9, 2 m, 58 type BNC/XTR9, 2 m, 58 type BNC/UHF wp, 2 m, 58 type BNC/UHF, 2 m, 58 type

BCXW-2.0-58
MCX5-2.0-74

XCX5-1.0-74

GCX9-2.0-74

BNC/XTRW, 2 m, 58 type M'dot/XTR5, 2 m, 174 type XTR/XTR5, 1 m, 174 type G/XTR9, 2 m, 174 type

BCMM-2.0-74
TCL9-2.0-74

DCV-1.5-58

DBCMM-2.0-74

BNC/MM, 2 m, 174 type TNC/XTR9, 2 m, 174 type DB/VC, 1.5 m, 58 type BNC/MM, 2 m, 174 type

 
±âŸ ŽÃËÀÚ
(ÀÚ¼¼ÇÑ ³»¿ëÀ» º¸·Á¸é À̹ÌÁö¸¦ Ŭ¸¯ÇϽʽÿÀ)
     
1. Introduction 2. Table of Contents 3. Technical Information 4. Contact Transducers
       
5. Protective Face Transducer 6. Standard Angle Beam Transducers and Wedges 7. Fingertip Angle Beam Transducers and Wedges 1 8. Fingertip Angle Beam Transducers and Wedges 2
       
9. Fingertip Angle Beam Transducers 10. Delay Line Transducers 11. Dual Element Transducers 1 12. Dual Element Transducers 2
       
13. Immersion Transducers 1 14. Immersion Transducers 2 15. Immersion Transducers 3 16. Cables, Search Tubes & Adaptors
       
17. Test Blocks 18. Transducer Certification 19. Specials 1 20 . Specials 2
       
   
21. Useful Information 1 22. Useful Information 2    
     
ÀÌ »çÀÌÆ®¿¡´Â NDT net¿¡¼­ Á¦°øÇÏ´Â ÃÊÀ½ÆÄ Å½ÃËÀÚ ¹× EMAT¿¡ ´ëÇÑ paper ¹× Çؼ³ÀÌ µé¾î ÀÖ½À´Ï´Ù.

     
5MHz ¼öÁ÷
2MHz ¼öÁ÷

 

109.jpg (6112 bytes)